DIN rail unit for switching 8 outputs from 230V ~ up to 16A in total. For switching lights or other electrical loads. The unit is also equipped with 4 binary inputs for voltage detection.
This module can control up to 8 outputs, with independent four-by-fours. It can control lights, sockets, any type of load in on/off mode.
Actuation on the outputs can be using the keys on the touch panel, mobile application, or even the buttons on the modules.
Actuation on the outputs can be using the keys on the touch panel, mobile application, or even the buttons on the modules.
We recommend the APP to associate an output to a key.
Go to the left menu and select PROGRAM, find the output and put it in programming by pressing the option on the right side, press the key (the output will no longer appear as in programming in the APP).
Note: While the PROG is in Red and the Output in Green in programming if someone presses another key than the desired one this will close the association with another key than the desired one.
We recommend the APP to associate an output to a key.
Go to the left menu and select PROGRAM, find the output and put it in programming by pressing the option on the right side, press the key (the output will no longer appear as in programming in the APP).
Note: While the PROG is in Red and the Output in Green in programming if someone presses another key than the desired one this will close the association with another key than the desired one.
To associate an output of a D-8ONOFF press the PROG button of that module and then press the button of the output to be controlled, then press the button you want to be triggering the output.
Note: While PROG is Red and Output is Green in programming if someone presses a button other than the one desired it will close the association with a button other than the one desired.
To associate an output of a D-8ONOFF press the PROG button of that module and then press the button of the output to be controlled, then press the button you want to be triggering the output.
Note: While PROG is Red and Output is Green in programming if someone presses a button other than the one desired it will close the association with a button other than the one desired.
Yes, for each output the module stores more than 20 keys.
Yes, for each output the module stores more than 20 keys.
We recommend the APP to associate the various outputs to a button.
Go to the left menu and select PROGRAM, find the outputs and put them in programming, press the button (the outputs will no longer appear as being in programming in the APP).
To associate several outputs in a single button, press PROG and the buttons of the several outputs you want to program together, then press the button you want to activate the outputs.
You can do the same steps on outputs of other modules at the same time (D-8ONOFF, D-4ONOFF or W-2ONOFF).
This process can be done all at once or in incremental steps per module, i.e. you can add output blocks to a key at different times.
Note: While PROG is Red and Output is Green in programming if someone presses a key other than the desired one it will close the association with a key other than the desired one.
We recommend the APP to associate the various outputs to a button.
Go to the left menu and select PROGRAM, find the outputs and put them in programming, press the button (the outputs will no longer appear as being in programming in the APP).
To associate several outputs in a single button, press PROG and the buttons of the several outputs you want to program together, then press the button you want to activate the outputs.
You can do the same steps on outputs of other modules at the same time (D-8ONOFF, D-4ONOFF or W-2ONOFF).
This process can be done all at once or in incremental steps per module, i.e. you can add output blocks to a key at different times.
Note: While PROG is Red and Output is Green in programming if someone presses a key other than the desired one it will close the association with a key other than the desired one.
Go to the left menu and select DELETE find the output(s) and put them on schedule, press the key, the output(s) will no longer appear as being on schedule in the APP.
Go to the left menu and select DELETE find the output(s) and put them on schedule, press the key, the output(s) will no longer appear as being on schedule in the APP.
On the module I press the “PROG” key and the red LED lights up.
Select the output(s) you want to remove the key from by pressing the corresponding button(s) and the green LED(s) will be lit.
Press for 2 seconds on the PROG key and the red LED will flash.
On the panel press the key you wish to remove the association from.
On the module I press the “PROG” key and the red LED lights up.
Select the output(s) you want to remove the key from by pressing the corresponding button(s) and the green LED(s) will be lit.
Press for 2 seconds on the PROG key and the red LED will flash.
On the panel press the key you wish to remove the association from.
Go to the left menu and select SET PANEL press a key on the panel that has the key you want to remove from all outputs.
Choose the key and in the COMMAND option choose DELETE then confirm with the check mark in the top right corner of the screen.
Go to the left menu and select SET PANEL press a key on the panel that has the key you want to remove from all outputs.
Choose the key and in the COMMAND option choose DELETE then confirm with the check mark in the top right corner of the screen.
Go to the menu on the left and select DELETE find exit and select the more options symbol on the right side of the screen. Confirm by selecting the option and validate by clicking on the checkmark in the top right corner.
Go to the menu on the left and select DELETE find exit and select the more options symbol on the right side of the screen. Confirm by selecting the option and validate by clicking on the checkmark in the top right corner.
Yes, you can make the outputs 5,6,7,8 of the D-8ONOFF module timed.
On the D-8ONOFF module, press the output button for 5 seconds and the output LED will blink once per second, which corresponds to a time of one second. By pressing the key you can blink 2,3,4,5,6 which corresponds to 1 minute, 5 minutes, 15 minutes, 30 minutes, 1 hour respectively.
After choosing the desired time press for 5 seconds to finish the process. The timing of the outputs (5, 6, 7, 8) must be done at the end of all other associations or programming.
The timing is of the output and therefore valid for any key that activates this output and thus prevails over keys with timers programmed via APP.
Yes, you can make the outputs 5,6,7,8 of the D-8ONOFF module timed.
On the D-8ONOFF module, press the output button for 5 seconds and the output LED will blink once per second, which corresponds to a time of one second. By pressing the key you can blink 2,3,4,5,6 which corresponds to 1 minute, 5 minutes, 15 minutes, 30 minutes, 1 hour respectively.
After choosing the desired time press for 5 seconds to finish the process. The timing of the outputs (5, 6, 7, 8) must be done at the end of all other associations or programming.
The timing is of the output and therefore valid for any key that activates this output and thus prevails over keys with timers programmed via APP.
Press for 5 seconds on the output button.
Press for 5 seconds on the output button.
Make sure that “PROG LOCK” is not active.
If in any D-BUSSUPPLY in the house the “LOCK” LED is flashing green repeatedly and constantly you have to press 2 seconds on the “LOCK” to remove this inhibition to programming.
Make sure that “PROG LOCK” is not active.
If in any D-BUSSUPPLY in the house the “LOCK” LED is flashing green repeatedly and constantly you have to press 2 seconds on the “LOCK” to remove this inhibition to programming.
The binary inputs are used to connect non-Atouch switches or detectors. This way it is possible to control or condition the actions of Atouch modules with third-party material.
Some examples are anemometers, twilight and presence detectors, conventional pushbutton switches for outdoor placement, pantries, other less noble or aggressive environments.
The inputs have 7 functions for the operation of the outputs.
We recommend, whenever possible, the use of the module dedicated to these functions D-16VIN.
The binary inputs are used to connect non-Atouch switches or detectors. This way it is possible to control or condition the actions of Atouch modules with third-party material.
Some examples are anemometers, twilight and presence detectors, conventional pushbutton switches for outdoor placement, pantries, other less noble or aggressive environments.
The inputs have 7 functions for the operation of the outputs.
We recommend, whenever possible, the use of the module dedicated to these functions D-16VIN.
These modules (REF 8800-0123) require the presence of 230VAC at the inputs. This connection must be of the same phase and differential.
Connections that do not respect the connection diagram are out of warranty.
These modules (REF 8800-0123) require the presence of 230VAC at the inputs. This connection must be of the same phase and differential.
Connections that do not respect the connection diagram are out of warranty.
These modules communicate via the FTC protocol on the BUS which is referenced to a neutral, meaning you only need one more wire in your house to ensure you have the BUS everywhere.
These modules communicate via the FTC protocol on the BUS which is referenced to a neutral, meaning you only need one more wire in your house to ensure you have the BUS everywhere.