d-4thermo

Programmable thermostat for DIN rail for 4-zone temperature scheduling. Can be used for underfloor heating, radiators and power switching modules of 4 independent circuits up to 16A.

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

D-4THERMO is a thermostat module to control up to 4 underfloor heating zones or similar, DIN rail mounting, which requires the zones to be paired with a T-OLED. Each panel that reports the temperature to turn on or off each heating in a room in the house. It is the T-OLED that reads and reports the temperature in the room where it is installed.

Among other functions, it performs weekly scheduling and summer/winter cycle control.

Yes, it has to be paired with a T-OLED like any module in the clima control range, in order to guarantee that it has a temperature probe to read and thus know whether to turn the machine on/off.

Yes, it has to be paired with a T-OLED like any module in the clima control range, in order to guarantee that it has a temperature probe to read and thus know whether to turn the machine on/off.

No. This module is for placement on a DIN rail or drop box and does not have any connections to support or power Atouch panels.

No. This module is for placement on a DIN rail or drop box and does not have any connections to support or power Atouch panels.

Each D-4THERMO output to be used must be paired with a T-OLED in secondary mode.

Each D-4THERMO output to be used must be paired with a T-OLED in secondary mode.

This module can control radiant floor solenoid valves at any domestic voltage or resistive loads up to 16A in total. Each of the 4 outputs needs to be paired with a T-OLED, ie up to 4 independent zones.

This module can control radiant floor solenoid valves at any domestic voltage or resistive loads up to 16A in total. Each of the 4 outputs needs to be paired with a T-OLED, ie up to 4 independent zones.

The D-4THERMO has 4 outputs and can therefore control up to 4 zones regardless of the number of solenoids per zone. In this way, you can add as many solenoids per output, remembering that this output will only measure the temperature on a T-OLED display. You can also place two T-OLEDs in a room and, by associating one with an independent output, have heating redundancy in a room or reinforcement at different temperatures.

The D-4THERMO has 4 outputs and can therefore control up to 4 zones regardless of the number of solenoids per zone. In this way, you can add as many solenoids per output, remembering that this output will only measure the temperature on a T-OLED display. You can also place two T-OLEDs in a room and, by associating one with an independent output, have heating redundancy in a room or reinforcement at different temperatures.

There is no limit of units per module type in an Atouch home.

There is no limit of units per module type in an Atouch home.

The cycle can be changed via App 3.0 or on a T-OLED associated with any thermostat.

In APP 3.0, press the clima control button on the bottom bar and choose the cycle.

On the T-OLED enter configuration mode and toggle the cycle from summer mode to winter mode.

The cycle can be changed via App 3.0 or on a T-OLED associated with any thermostat.

In APP 3.0, press the clima control button on the bottom bar and choose the cycle.

On the T-OLED enter configuration mode and toggle the cycle from summer mode to winter mode.

The cycle can be changed via App 3.0 or on a T-OLED associated with a thermostat.

In the App, press the clima control button on the bottom bar and choose the cycle.

On the T-OLED enter configuration mode and toggle the cycle from summer mode to winter mode.

The cycle can be changed via App 3.0 or on a T-OLED associated with a thermostat.

In the App, press the clima control button on the bottom bar and choose the cycle.

On the T-OLED enter configuration mode and toggle the cycle from summer mode to winter mode.

In order to have two machines in a single room and in a single panel T-OLED with probe, a chained pairing is necessary, so the T-OLED is paired with the Thermo, which will be the main machine in the room, and then the secondary machine is programmed to follow the primary.

In order to have two machines in a single room and in a single panel T-OLED with probe, a chained pairing is necessary, so the T-OLED is paired with the Thermo, which will be the main machine in the room, and then the secondary machine is programmed to follow the primary.

To define the type and machine you will have to enter the configuration menu.

On the T-OELD panel, ensure that it is in climate control mode.

Make sure the thermostat is turned off by pressing the top left key.

Press for 5 seconds on the lower left key until you enter the menu. Use the (-) key to navigate to the “Unit Type” menu and choose by pressing the lower left key.

To define the type and machine you will have to enter the configuration menu.

On the T-OELD panel, ensure that it is in climate control mode.

Make sure the thermostat is turned off by pressing the top left key.

Press for 5 seconds on the lower left key until you enter the menu. Use the (-) key to navigate to the “Unit Type” menu and choose by pressing the lower left key.

To edit the schedule you will have to enter the menu.

On the T-OELD panel, ensure that it is in climate control mode.

Make sure the thermostat is turned off by pressing the top left key.

Press for 5 seconds on the lower left key until you enter the menu.

The first option will appear as “Program” by pressing the lower left key and change between “On” and “Off”, confirm by pressing the lower left key.

The “Cycle” option will appear and you can choose Winter or Summer.

Navigate to “Summer” and “Winter” and set the times and temperatures by day of the week for each of the cycles.

To edit the schedule you will have to enter the menu.

On the T-OELD panel, ensure that it is in climate control mode.

Make sure the thermostat is turned off by pressing the top left key.

Press for 5 seconds on the lower left key until you enter the menu.

The first option will appear as “Program” by pressing the lower left key and change between “On” and “Off”, confirm by pressing the lower left key.

The “Cycle” option will appear and you can choose Winter or Summer.

Navigate to “Summer” and “Winter” and set the times and temperatures by day of the week for each of the cycles.

You can change the temperature in two ways via the APP or via the panel where you measure the temperature to be changed:

a) APP – In the lower bar, navigate to Climate Control, find the room you want to change and increase or decrease the “Target Temperature” using the “+” and “-“;

b) On the room panel, ensure that it is in clima control mode

Check whether it is on or off by pressing the key and press the “+” and “-” key to change the “Target Temperature”.

If you have the schedule turned on, these actions overlap until the next scheduled event.

You can change the temperature in two ways via the APP or via the panel where you measure the temperature to be changed:

a) APP – In the lower bar, navigate to Climate Control, find the room you want to change and increase or decrease the “Target Temperature” using the “+” and “-“;

b) On the room panel, ensure that it is in clima control mode

Check whether it is on or off by pressing the key and press the “+” and “-” key to change the “Target Temperature”.

If you have the schedule turned on, these actions overlap until the next scheduled event.

These changes are in effect until the next scheduled event occurs. If you do not have active schedules in the “Program” Menu, they will remain until you change them again.

These changes are in effect until the next scheduled event occurs. If you do not have active schedules in the “Program” Menu, they will remain until you change them again.

Yes, a T-OLED paired with 1 or 2 Thermo modules controlling 1 or 2 machines for the same room can always remain in secondary Air Conditioning.

To permanently switch between Primary automation mode and Secondary clima control mode, press the lower left and upper right buttons simultaneously for 5 seconds. The presence or absence of

If you have automation mode and just want to change it temporarily press the keys momentarily.

Yes, a T-OLED paired with 1 or 2 Thermo modules controlling 1 or 2 machines for the same room can always remain in secondary Air Conditioning.

To permanently switch between Primary automation mode and Secondary clima control mode, press the lower left and upper right buttons simultaneously for 5 seconds. The presence or absence of

If you have automation mode and just want to change it temporarily press the keys momentarily.

This module can be mounted anywhere, as long as the BUS communication and humidity conditions are safeguarded so that it works correctly.

This module can be mounted anywhere, as long as the BUS communication and humidity conditions are safeguarded so that it works correctly.

No, this module does not have binary inputs. Although they have electrical connectors equivalent to the D8/4ONOFF and D-4/2SHUTT, they lack functionality.

The inputs are used to connect motion sensors, brightness, timers or others.

No, this module does not have binary inputs. Although they have electrical connectors equivalent to the D8/4ONOFF and D-4/2SHUTT, they lack functionality.

The inputs are used to connect motion sensors, brightness, timers or others.

To reset this module to its original settings, press the PROG button for 10 seconds. This will clear the name, panel association and all machine parameters.

To reset this module to its original settings, press the PROG button for 10 seconds. This will clear the name, panel association and all machine parameters.